Register  
Sunday, May 20, 2012
Home » Products  
Related Links

Weitzer Sales

Current Articles | Categories | Search | Syndication

Friday, December 04, 2009
700F Power Processor
By Administrator Account @ 9:36 AM :: 254 Views :: Power Quality Products, Power Regulation, Power Conditioning
 

Controlled Power Company has introduced the 700F Power Processor

                                 

  • Front access only! All installation, operation, maintenance, and testing can occur from the front of the unit — no side or rear access required.
  • 7-tap, microprocessor-controlled for tight voltage regulation, accuracy, and stability.
  • Precisely maintains correct voltage to ± 3% within 1 cycle, and maintains regulation during extended brownouts.
  • Extended input regulation range options including +10%, -40%; +15%, -25%; and +20%, -30%
  • Low output impedance transformer minimizes voltage distortion and sags commonly associated with high surge currents.
  • Triple-shielded isolation transformer provides a noise-free ground, attenuates voltage spikes and transients, and re-establishes the N-G bond.
  • Internal manual bypass option maintains system isolation, voltage transformation, and power conditioning.
  • Superior compatibility with dynamic loads.
  • Increased surge capability, without the need for automatic bypassing, provides full-time power conditioning.
  • High-efficiency design results in lower operating cost.

Technical Specs:

  • Input Operating Voltage Range: +10%, - 20% from nominal (Extended regulation range options available.)
  • Input Frequency: 60 Hz, ± 3%
  • Input Power Factor: > .99 PF with resistive load
  • Reflected Harmonics: Triplen harmonics are not reflected to the utility under non-linear loads
  • Output Line Voltage Regulation: ± 3% from nominal
  • Response Time: < 1/2 cycle
  • Correction Time: 1 cycle
  • Load Regulation: 2.5% typical, no load to full load
  • Overload Rating: 200% for 10 seconds; 1000% for 1 cycle
  • Common Mode Noise Attenuation: 146dB
  • Transverse Mode: 3 dB down at 1kHz; 40 dB down per decade to below 50 dB with a resistive load
  • Transient Voltage Suppression: Meets ANSI C62.41 Category B-3
  • Efficiency: 96% - 97% typical, model and load dependant
  • UL 1012 Listed, C-UL Listed to CSA C22.2, No. 107.1-01

Applications

  • Pharmaceuticals / Labs
  • Government / Commercial Buildings
  • Broadcast Communications
  • Telecommunications
  • Concert Halls / Theaters
  • Wastewater Treatment Plants
  • Refineries / PetroChem
  • Aerospace
  • Printing Presses
  • Industrial Lasers
  • Pulp / Paper Mills
  • Food Processing Plants
  • UPS Bypass & Power Distribution